Version 5.1 AddendumLabVIEW 5.1 AddendumFebruary 1999 EditionPart Number 322179A-01
Chapter 1 Required Configuration, Installation, and Upgrade InformationLabVIEW 5.1 Addendum 1-2© National Instruments CorporationTable 1-1. Installat
Appendix A Manual Clarifications and Additions© National Instruments Corporation A-11 LabVIEW 5.1 Addendum-1073807252 VI_ERROR_ASRL_OVERRUN An overrun
© National Instruments Corporation I-1 LabVIEW 5.1 AddendumIndexNumbers3D graph controls for Windows, 2-9Aaccessing recently opened files, 2-4 to 2-5A
IndexLabVIEW 5.1 Addendum I-2© National Instruments Corporationconverting VIs, 1-18CVI Functional Panel Converter, manual changes for, A-2Ddata acquis
Index© National Instruments Corporation I-3 LabVIEW 5.1 AddendumHiQ and MATLAB functionality for Windows, 2-15 to 2-22integration of mathematics and s
IndexLabVIEW 5.1 Addendum I-4© National Instruments CorporationLinux, 1-8 to 1-9Macintosh, 1-6 to 1-7more information about LabVIEW, 1-9notes, 1-9 to
Index© National Instruments Corporation I-5 LabVIEW 5.1 AddendumPower Macintosh installation requirements (table), 1-3sound VIs, 2-25support for NI-DA
IndexLabVIEW 5.1 Addendum I-6© National Instruments Corporationdiscontinued platform support, 1-5installation requirements (table), 1-2 to 1-4installi
Index© National Instruments Corporation I-7 LabVIEW 5.1 AddendumFind All Instances and Search Results dialog box, 2-5 to 2-6Find dialog box, 2-5server
IndexLabVIEW 5.1 Addendum I-8© National Instruments Corporationsaving for previous version, 2-4Signal Generator by Duration VI, A-2sound VIs for Windo
Chapter 1 Required Configuration, Installation, and Upgrade Information© National Instruments Corporation 1-3 LabVIEW 5.1 AddendumPower Macintosh Dist
Chapter 1 Required Configuration, Installation, and Upgrade InformationLabVIEW 5.1 Addendum 1-4© National Instruments CorporationOperating System Patc
Chapter 1 Required Configuration, Installation, and Upgrade Information© National Instruments Corporation 1-5 LabVIEW 5.1 AddendumDistribution Changes
Chapter 1 Required Configuration, Installation, and Upgrade InformationLabVIEW 5.1 Addendum 1-6© National Instruments CorporationInstalling LabVIEWIf
Chapter 1 Required Configuration, Installation, and Upgrade Information© National Instruments Corporation 1-7 LabVIEW 5.1 AddendumNote The installer g
Chapter 1 Required Configuration, Installation, and Upgrade InformationLabVIEW 5.1 Addendum 1-8© National Instruments Corporation3. If your CD was mou
Chapter 1 Required Configuration, Installation, and Upgrade Information© National Instruments Corporation 1-9 LabVIEW 5.1 Addendum3. To change the cur
Chapter 1 Required Configuration, Installation, and Upgrade InformationLabVIEW 5.1 Addendum 1-10© National Instruments CorporationFor More Information
Chapter 1 Required Configuration, Installation, and Upgrade Information© National Instruments Corporation 1-11 LabVIEW 5.1 AddendumYou can find furthe
Internet SupportE-mail: [email protected] Site: ftp.natinst.comWeb Address: http://www.natinst.comBulletin Board SupportBBS United States: 512 79
Chapter 1 Required Configuration, Installation, and Upgrade InformationLabVIEW 5.1 Addendum 1-12© National Instruments CorporationInstalling HiQ for W
Chapter 1 Required Configuration, Installation, and Upgrade Information© National Instruments Corporation 1-13 LabVIEW 5.1 AddendumLow-Level Register
Chapter 1 Required Configuration, Installation, and Upgrade InformationLabVIEW 5.1 Addendum 1-14© National Instruments CorporationConfiguring LabVIEW
Chapter 1 Required Configuration, Installation, and Upgrade Information© National Instruments Corporation 1-15 LabVIEW 5.1 Addendum(Motif) To change t
Chapter 1 Required Configuration, Installation, and Upgrade InformationLabVIEW 5.1 Addendum 1-16© National Instruments Corporation3. At the ok prompt,
Chapter 1 Required Configuration, Installation, and Upgrade Information© National Instruments Corporation 1-17 LabVIEW 5.1 Addendumprevious versions.
Chapter 1 Required Configuration, Installation, and Upgrade InformationLabVIEW 5.1 Addendum 1-18© National Instruments CorporationConverting VIsUpgrad
Chapter 1 Required Configuration, Installation, and Upgrade Information© National Instruments Corporation 1-19 LabVIEW 5.1 AddendumYou must upgrade th
© National Instruments Corporation 2-1 LabVIEW 5.1 Addendum2New Features in LabVIEW 5.1This chapter describes the features added and the significant c
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-2© National Instruments Corporation• Once an object scales itself automatically, it might
Important InformationWarrantyThe media on which you receive National Instruments software are warranted not to fail to execute programming instructio
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-3 LabVIEW 5.1 AddendumSetting All Objects on a Front Panel to ScaleYou can d
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-4© National Instruments CorporationSaving for a Previous VersionWith LabVIEW 5.1, you can
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-5 LabVIEW 5.1 AddendumWhen you choose File»Recently Opened Files, a submenu
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-6© National Instruments CorporationTo find all instances of an object, right-click the obj
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-7 LabVIEW 5.1 AddendumNew VIs, Functions, and ControlsThis section describes
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-8© National Instruments CorporationDialog ControlsAll the dialog controls are now grouped
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-9 LabVIEW 5.1 Addendumplatform. The Dialog Recessed Frame control behaves li
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-10© National Instruments CorporationWith LabVIEW 5.1, in addition to the VIs that previous
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-11 LabVIEW 5.1 Addendum• History»Prompt for Comments at Save • History»Recor
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-12© National Instruments CorporationIVI Instrument Drivers and ActiveXSome parameters for
© National Instruments Corporation v LabVIEW 5.1 AddendumContentsAbout This AddendumChapter 1Required Configuration, Installation, and Upgrade Informa
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-13 LabVIEW 5.1 AddendumTo access the ring constant when building an ActiveX
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-14© National Instruments Corporation3. Wire the Automation refnum from the container termi
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-15 LabVIEW 5.1 AddendumHiQ and MATLAB Functionality for WindowsHiQ and MATLA
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-16© National Instruments CorporationCreating a HiQ ScriptComplete the following instructio
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-17 LabVIEW 5.1 Addendum7. To add inputs and outputs for variables, right-cli
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-18© National Instruments CorporationCreating a MATLAB ScriptComplete the following instruc
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-19 LabVIEW 5.1 Addendum7. Run the VI. LabVIEW launches MATLAB and a new MATL
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-20© National Instruments CorporationScrolling through a HiQ or MATLAB ScriptJust as with a
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-21 LabVIEW 5.1 AddendumDebugging a HiQ or MATLAB ScriptUse the following pro
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-22© National Instruments CorporationError CodesThe following table explains error messages
ContentsLabVIEW 5.1 Addendum vi© National Instruments CorporationChapter 2New Features in LabVIEW 5.1Dialog Box, Menu, and Window Enhancements ...
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-23 LabVIEW 5.1 AddendumFor function and reference information about the Math
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-24© National Instruments CorporationSignal Processing PaletteFor function and reference in
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-25 LabVIEW 5.1 AddendumNote The Picture Control VIs are available on all pla
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-26© National Instruments CorporationTo create reports using the Report Generation VIs, go
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-27 LabVIEW 5.1 AddendumSee the Easy Text Report VI description in the Report
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-28© National Instruments CorporationReport Generation VI DescriptionsThis section describe
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-29 LabVIEW 5.1 AddendumThe Report Generation palette has two subpalettes:• F
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-30© National Instruments CorporationFont Settings indicates what font settings currently a
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-31 LabVIEW 5.1 Addendumleft is the information you want to appear in the lef
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-32© National Instruments Corporationorientation specifies how the report appears when it i
Contents© National Instruments Corporation vii LabVIEW 5.1 AddendumAppendix AManual Clarifications and AdditionsMultithreading ...
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-33 LabVIEW 5.1 AddendumText Options specifies how the text appears in the re
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-34© National Instruments CorporationYou might find using tokens with this VI helpful, part
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-35 LabVIEW 5.1 AddendumAppend Numeric Table to ReportTakes a 2D array of num
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-36© National Instruments CorporationDispose ReportCloses the report and releases its inter
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-37 LabVIEW 5.1 AddendumNew Report PageAdds a new page in the report to which
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-38© National Instruments CorporationSet Report Header TextSets the text for the VI header.
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-39 LabVIEW 5.1 AddendumSet Report Tab WidthSets the tab width in the report.
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-40© National Instruments CorporationIf you are scanning modules, you can scan an arbitrary
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-41 LabVIEW 5.1 Addendumthree VIs could be found on the VISA Serial palette b
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-42© National Instruments CorporationBuilding an ApplicationComplete the following instruct
ContentsLabVIEW 5.1 Addendum viii© National Instruments CorporationTablesTable 1-1. Installation Requirements ...
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-43 LabVIEW 5.1 Addendumc. If you want to add support files, click Add Suppor
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-44© National Instruments CorporationActiveX server. When you build an application myapp.ex
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-45 LabVIEW 5.1 AddendumNote This completes the build application process on
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-46© National Instruments Corporationfile or a registry file. Install the file as part of y
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-47 LabVIEW 5.1 AddendumEnhancements to NetworkingThis section describes the
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-48© National Instruments CorporationThe Web ServerWith the Web Server in LabVIEW, you can
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-49 LabVIEW 5.1 AddendumThe Web Server Browser Access Dialog BoxThe Web Serve
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-50© National Instruments CorporationTable 2-7 describes the available options.When a brows
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-51 LabVIEW 5.1 AddendumFor example, if you give a.test.site.com and b.test.s
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-52© National Instruments CorporationThe Web Server Visible VIs Dialog BoxBecause the Web S
© National Instruments Corporation ix LabVIEW 5.1 AddendumAbout This AddendumThis addendum describes all of the new LabVIEW 5.1 features, compatibilit
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-53 LabVIEW 5.1 AddendumTable 2-9 describes the available options.Each entry
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-54© National Instruments Corporationhow that entry is set up. If a subsequent entry also m
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-55 LabVIEW 5.1 Addendumthe string srvr_ and ends with the string .vi is expo
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-56© National Instruments CorporationPublishing Front Panel Images on the WebComplete the f
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-57 LabVIEW 5.1 AddendumViewing an Animated Version of a Front PanelComplete
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-58© National Instruments CorporationWhat URLs Can I Use with My Front Panel Images?With th
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-59 LabVIEW 5.1 AddendumThe syntax to use in the URL for static front panel i
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-60© National Instruments CorporationThe following are some examples on how you would use t
Chapter 2 New Features in LabVIEW 5.1© National Instruments Corporation 2-61 LabVIEW 5.1 AddendumThe syntax to use in the URL for static front panel i
Chapter 2 New Features in LabVIEW 5.1LabVIEW 5.1 Addendum 2-62© National Instruments CorporationLifespan is the number of seconds the front panel anim
© National Instruments Corporation 1-1 LabVIEW 5.1 Addendum1Required Configuration, Installation, and Upgrade InformationThis chapter describes the sy
© National Instruments Corporation A-1 LabVIEW 5.1 AddendumAManual Clarifications and AdditionsThis appendix clarifies and corrects information in the
Appendix A Manual Clarifications and AdditionsLabVIEW 5.1 Addendum A-2© National Instruments CorporationData Format—The compatibility VIs for the LabV
Appendix A Manual Clarifications and Additions© National Instruments Corporation A-3 LabVIEW 5.1 Addendumpalettes are skipped. Unlike icon palettes, y
Appendix A Manual Clarifications and AdditionsLabVIEW 5.1 Addendum A-4© National Instruments CorporationFigure A-1. File Manager Tool Dialog BoxIf yo
Appendix A Manual Clarifications and Additions© National Instruments Corporation A-5 LabVIEW 5.1 Addendumcontain characters that are invalid on some p
Appendix A Manual Clarifications and AdditionsLabVIEW 5.1 Addendum A-6© National Instruments CorporationConfiguration File VIs—The Configuration File
Appendix A Manual Clarifications and Additions© National Instruments Corporation A-7 LabVIEW 5.1 AddendumSupport for Template VIs and ControlsYou can
Appendix A Manual Clarifications and AdditionsLabVIEW 5.1 Addendum A-8© National Instruments Corporation• The LabVIEW priority system is reflected in
Appendix A Manual Clarifications and Additions© National Instruments Corporation A-9 LabVIEW 5.1 Addendum• In Chapter 6, Strings and File I/O, the blo
Appendix A Manual Clarifications and AdditionsLabVIEW 5.1 Addendum A-10© National Instruments Corporation1073676421 VI_WARN_UNKNOWN_STATUS The status
Komentáře k této Příručce