National Instruments NI-488.2 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Software National Instruments NI-488.2. National Instruments NI-488.2 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 172
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - NI-488.2

© Copyright 1993, 1996 National Instruments Corporation.All Rights Reserved.NI-488.2™User Manual for WindowsJanuary 1996 EditionPart Number 370902A-01

Strany 2

ContentsNI-488.2 User Manual for Windows x © National Instruments Corp.Exiting wibconf ...

Strany 3 - Limited Warranty

© National Instruments Corp. 7-1 NI-488.2 User Manual for WindowsChapter 7GPIB Programming Techniques

Strany 4 - Trademarks

GPIB Programming Techniques Chapter 7NI-488.2 User Manual for Windows 7-2 © National Instruments Corp.You can use the ibconfig function to configure t

Strany 5 - Contents

Chapter 7 GPIB Programming Techniques© National Instruments Corp. 7-3 NI-488.2 User Manual for Windowscable in your system. It is called the Configur

Strany 6

GPIB Programming Techniques Chapter 7NI-488.2 User Manual for Windows 7-4 © National Instruments Corp.• If your setup includes more than one Controlle

Strany 7 - Chapter 5

Chapter 7 GPIB Programming Techniques© National Instruments Corp. 7-5 NI-488.2 User Manual for WindowsUsing the Event QueueSome applications need to k

Strany 8 - GPIB Spy

GPIB Programming Techniques Chapter 7NI-488.2 User Manual for Windows 7-6 © National Instruments Corp.Service Requests from IEEE 488.2 DevicesThe IEEE

Strany 9

Chapter 7 GPIB Programming Techniques© National Instruments Corp. 7-7 NI-488.2 User Manual for WindowsIf no device responds positively to the serial p

Strany 10

GPIB Programming Techniques Chapter 7NI-488.2 User Manual for Windows 7-8 © National Instruments Corp.if ( ibsta & RQS ) {printf ( "Device a

Strany 11

Chapter 7 GPIB Programming Techniques© National Instruments Corp. 7-9 NI-488.2 User Manual for WindowsExample 1: Using FindRQSThis example illustrate

Strany 12 - About This Manual

GPIB Programming Techniques Chapter 7NI-488.2 User Manual for Windows 7-10 © National Instruments Corp./* Use Allspoll to serial poll all the devices

Strany 13 - Organization of This Manual

Contents© National Instruments Corp. xi NI-488.2 User Manual for WindowsTablesTable 1-1. GPIB Handshake Lines ...

Strany 14

Chapter 7 GPIB Programming Techniques© National Instruments Corp. 7-11 NI-488.2 User Manual for WindowsS is 1 if the device is to assert the assigned

Strany 15 - Related Documentation

GPIB Programming Techniques Chapter 7NI-488.2 User Manual for Windows 7-12 © National Instruments Corp.Parallel Polling with NI-488.2 RoutinesFollow t

Strany 16 - Introduction

© National Instruments Corp. 8-1 NI-488.2 User Manual for WindowsChapter 8wibconf–Windows Interface BusConfiguration Utility

Strany 17 - GPIB Addressing

wibconf-Windows Interface Bus Configuration Utility Chapter 8NI-488.2 User Manual for Windows 8-2 © National Instruments Corp.Table 8-1 lists the opti

Strany 18

Chapter 8 wibconf-Windows Interface Bus Configuration Utility© National Instruments Corp. 8-3 NI-488.2 User Manual for WindowsUpper-Level Device MapFi

Strany 19

wibconf-Windows Interface Bus Configuration Utility Chapter 8NI-488.2 User Manual for Windows 8-4 © National Instruments Corp.Device Maps of Use <

Strany 20 - Configuration Requirements

Chapter 8 wibconf-Windows Interface Bus Configuration Utility© National Instruments Corp. 8-5 NI-488.2 User Manual for WindowsEdit Use the function ke

Strany 21 - The NI-488.2 Software Package

wibconf-Windows Interface Bus Configuration Utility Chapter 8NI-488.2 User Manual for Windows 8-6 © National Instruments Corp.You can access the lower

Strany 22 - Visual Basic Language Files

Chapter 8 wibconf-Windows Interface Bus Configuration Utility© National Instruments Corp. 8-7 NI-488.2 User Manual for WindowsBoard and Device Configu

Strany 23 - Sample Application Files

wibconf-Windows Interface Bus Configuration Utility Chapter 8NI-488.2 User Manual for Windows 8-8 © National Instruments Corp.Serial Poll Timeouts (De

Strany 24

© National Instruments Corp. xiii NI-488.2 User Manual for WindowsAbout This Manual

Strany 25 - Application Examples

Chapter 8 wibconf-Windows Interface Bus Configuration Utility© National Instruments Corp. 8-9 NI-488.2 User Manual for WindowsSend EOI at End of Write

Strany 26

wibconf-Windows Interface Bus Configuration Utility Chapter 8NI-488.2 User Manual for Windows 8-10 © National Instruments Corp.Bus Timing (Board Chara

Strany 27

Chapter 8 wibconf-Windows Interface Bus Configuration Utility© National Instruments Corp. 8-11 NI-488.2 User Manual for WindowsDMA Channel (Board Char

Strany 28

wibconf-Windows Interface Bus Configuration Utility Chapter 8NI-488.2 User Manual for Windows 8-12 © National Instruments Corp.Default Configurations

Strany 29

Chapter 8 wibconf-Windows Interface Bus Configuration Utility© National Instruments Corp. 8-13 NI-488.2 User Manual for WindowsChecking for ErrorsUnle

Strany 30 - Example 3: Asynchronous I/O

wibconf-Windows Interface Bus Configuration Utility Chapter 8NI-488.2 User Manual for Windows 8-14 © National Instruments Corp.The following example i

Strany 31

Chapter 8 wibconf-Windows Interface Bus Configuration Utility© National Instruments Corp. 8-15 NI-488.2 User Manual for WindowsTable 8-2. wibconf Bat

Strany 32

© National Instruments Corp. A-1 NI-488.2 User Manual for WindowsAppendix AStatus Word Conditions

Strany 33

Status Word Conditions Appendix ANI-488.2 User Manual for Windows A-2 © National Instruments Corp.ERR (dev, brd)ERR is set in the status word followin

Strany 34 - Example 5: Service Requests

Appendix A Status Word Conditions© National Instruments Corp. A-3 NI-488.2 User Manual for WindowsAn automatic serial poll occurs either as a result o

Strany 35

About This ManualNI-488.2 User Manual for Windows xiv © National Instruments Corp.Organization of This ManualThis manual is organized as follows:• Cha

Strany 36 - (continues)

Status Word Conditions Appendix ANI-488.2 User Manual for Windows A-4 © National Instruments Corp.REM (brd)REM indicates whether or not the board is i

Strany 37 - (Continued)

Appendix A Status Word Conditions© National Instruments Corp. A-5 NI-488.2 User Manual for WindowsDTAS (brd)DTAS indicates whether the GPIB board has

Strany 38 - IEEE 488.2-Compliant Devices

© National Instruments Corp. B-1 NI-488.2 User Manual for WindowsAppendix BError Codes and Solutions

Strany 39

Error Codes and Solutions Appendix BNI-488.2 User Manual for Windows B-2 © National Instruments Corp.• An invalid unit descriptor is passed to any fun

Strany 40

Appendix B Error Codes and Solutions© National Instruments Corp. B-3 NI-488.2 User Manual for WindowsSolutions• Use ibsic or SendIFC to make the GPIB

Strany 41 - "SRQ=HI"

Error Codes and Solutions Appendix BNI-488.2 User Manual for Windows B-4 © National Instruments Corp.Solutions• Make sure that the GPIB board is addre

Strany 42 - Example 8: Parallel Polls

Appendix B Error Codes and Solutions© National Instruments Corp. B-5 NI-488.2 User Manual for WindowsEABO (6)EABO indicates that an I/O operation has

Strany 43

Error Codes and Solutions Appendix BNI-488.2 User Manual for Windows B-6 © National Instruments Corp.If you are using Windows 3.0 with DMA for data tr

Strany 44

Appendix B Error Codes and Solutions© National Instruments Corp. B-7 NI-488.2 User Manual for WindowsSolutionsResynchronize the driver and the applica

Strany 45

Error Codes and Solutions Appendix BNI-488.2 User Manual for Windows B-8 © National Instruments Corp.EBUS (14)EBUS results when certain GPIB bus error

Strany 46 - Developing Your Application

About This Manual© National Instruments Corp. xv NI-488.2 User Manual for WindowsConventions Used in This ManualThe following conventions are used in

Strany 47

Appendix B Error Codes and Solutions© National Instruments Corp. B-9 NI-488.2 User Manual for WindowsAlthough the occurrence of ESRQ warns you of a de

Strany 48 - Status Word – ibsta

© National Instruments Corp. C-1 NI-488.2 User Manual for WindowsAppendix CCustomer Communication

Strany 49

Technical Support Form

Strany 50 - Error Variable – iberr

National Instruments software product Version

Strany 51 - Items to Include

Documentation Comment Form

Strany 52 - NI-488 Program Shell

If you find errors in the manual, please record the page numbers and describe the errors.

Strany 53

© National Instruments Corp. Glossary-1 NI-488.2 User Manual for WindowsGlossary

Strany 54

GlossaryNI-488.2 User Manual for Windows Glossary-2 © National Instruments Corp.CCFE Configuration Enable is the GPIB command which precedesCFGn and i

Strany 55

Glossary© National Instruments Corp. Glossary-3 NI-488.2 User Manual for WindowsEEND or END message A message that signals the end of a data string.

Strany 56

GlossaryNI-488.2 User Manual for Windows Glossary-4 © National Instruments Corp.Hhandshake The mechanism used to transfer bytes from the SourceHandsha

Strany 57 - NI-488.2 Program Shell

About This ManualNI-488.2 User Manual for Windows xvi © National Instruments Corp.Related DocumentationThe following documents contain information tha

Strany 58

Glossary© National Instruments Corp. Glossary-5 NI-488.2 User Manual for WindowsKKB Kilobytes.LLAD (Listen Address) See MLA .language interface Code t

Strany 59

GlossaryNI-488.2 User Manual for Windows Glossary-6 © National Instruments Corp.NNDAC One of the three GPIB handshake lines. See(Not Data Accepted)

Strany 60

Glossary© National Instruments Corp. Glossary-7 NI-488.2 User Manual for WindowsSs Seconds.SDC Selected Device Clear is the GPIB command used to rese

Strany 61

GlossaryNI-488.2 User Manual for Windows Glossary-8 © National Instruments Corp.TTAD (Talk Address) See MTA .Talker A GPIB device that sends data mes

Strany 62 - Borland C++

© National Instruments Corp. Index-1 NI-488.2 User Manual for WindowsIndex

Strany 63 - Direct Entry with C

IndexNI-488.2 User Manual for Windows Index-2 © National Instruments Corp.opening devices, 3-8placing device offline, 3-10processing of data, 3-10prog

Strany 64

Index© National Instruments Corp. Index-3 NI-488.2 User Manual for WindowsBbase I/O address, setting, 8-10batch mode for wibconf utility, 8-13 to 8-15

Strany 65 - HINSTANCE GpibLib = NULL;

IndexNI-488.2 User Manual for Windows Index-4 © National Instruments Corp.compiling, linking, and running applicationsBorland C++, 3-17direct entry wi

Strany 66

Index© National Instruments Corp. Index-5 NI-488.2 User Manual for Windowsglobal status variables, 4-3GPIB error codes (table), 4-4 to 4-5GPIB Spy uti

Strany 67

IndexNI-488.2 User Manual for Windows Index-6 © National Instruments Corp.EBUS error codedefinition (table), 4-5description, B-8ECAP error codedefinit

Strany 68

© National Instruments Corp. 1-1 NI-488.2 User Manual for WindowsChapter 1Introduction

Strany 69 - Debugging Your Application

Index© National Instruments Corp. Index-7 NI-488.2 User Manual for Windowserror codes and solutionsEABO, B-5EADR, B-3 to B-4EARG, B-4EBUS, B-8ECAP, B-

Strany 70 - Running GPIBInfo

IndexNI-488.2 User Manual for Windows Index-8 © National Instruments Corp.Ffax technical support, C-1FindLstn routine, 3-13FindRQS routine, 7-8, 7-9fu

Strany 71

Index© National Instruments Corp. Index-9 NI-488.2 User Manual for Windowsserial polling, 7-5 to 7-10automatic serial polling, 7-6 to 7-7autopolling a

Strany 72 - GPIB Error Codes

IndexNI-488.2 User Manual for Windows Index-10 © National Instruments Corp.high-speed data transfers (HS488), 7-2 to 7-3enabling HS488, 7-2 to 7-3sett

Strany 73 - Configuration Errors

Index© National Instruments Corp. Index-11 NI-488.2 User Manual for Windowsibrsp functionconducting serial polls, 7-6, 7-7 to 7-8using in wibic, examp

Strany 74 - Communication Errors

IndexNI-488.2 User Manual for Windows Index-12 © National Instruments Corp.messages, sending across GPIB, 1-2 to 1-3data lines, 1-2handshake lines, 1-

Strany 75 - Common Questions

Index© National Instruments Corp. Index-13 NI-488.2 User Manual for Windowsplacing board offline, 3-16processing of data, 3-16program shell (illustrat

Strany 76

IndexNI-488.2 User Manual for Windows Index-14 © National Instruments Corp.Pparallel polling, 7-10 to 7-12application example, 2-18 to 2-19implementin

Strany 77

Index© National Instruments Corp. Index-15 NI-488.2 User Manual for WindowsSsecondary GPIB addressdefinition, 1-2setting, 8-7Send routineconfiguring i

Strany 78 - Control Utility

IndexNI-488.2 User Manual for Windows Index-16 © National Instruments Corp.status word - ibsta, 3-3 to 3-4ATN, A-4CIC, A-4CMPL, A-3DCAS, 7-4, A-5DTAS,

Strany 79

Introduction Chapter 1NI-488.2 User Manual for Windows 1-2 © National Instruments Corp.GPIB AddressingAll GPIB devices and boards must be assigned a u

Strany 80

Index© National Instruments Corp. Index-17 NI-488.2 User Manual for WindowsTIMO status word conditionbit position, hex value, and type (table), 3-4des

Strany 81 - Number Syntax

IndexNI-488.2 User Manual for Windows Index-18 © National Instruments Corp.terminate read on EOS, 8-8timeout setting, 8-7type of compare on EOS, 8-8us

Strany 82 - Address Syntax

Index© National Instruments Corp. Index-19 NI-488.2 User Manual for WindowsNI-488 functionsexamples, 5-1 to 5-4ibdev, 5-10 to 5-12ibfind, 5-10ibrd, 5-

Strany 83

Chapter 1 Introduction© National Instruments Corp. 1-3 NI-488.2 User Manual for WindowsHandshake LinesThree hardware handshake lines asynchronously co

Strany 84

Introduction Chapter 1NI-488.2 User Manual for Windows 1-4 © National Instruments Corp.Setting Up and Configuring Your SystemDevices are usually conne

Strany 85 - buffer v

National Instruments Corporate Headquarters6504 Bridge Point ParkwayAustin, TX 78730-5039(512) 794-0100Technical support fax: (800) 328-2203(512) 794-

Strany 86 - Error Information

Chapter 1 Introduction© National Instruments Corp. 1-5 NI-488.2 User Manual for WindowsControlling More Than One BoardMultiboard drivers, such as the

Strany 87 - Common NI-488 Functions

Introduction Chapter 1NI-488.2 User Manual for Windows 1-6 © National Instruments Corp.For high-speed operation, the following restrictions apply:• Al

Strany 88

Chapter 1 Introduction© National Instruments Corp. 1-7 NI-488.2 User Manual for Windows• ibdiag.exe is a program that you can use to test the GPIB har

Strany 89

Introduction Chapter 1NI-488.2 User Manual for Windows 1-8 © National Instruments Corp.Win 32s Files• gpib-32.dll is a 32-bit translation dynamic link

Strany 90 - Send and SendList

Chapter 1 Introduction© National Instruments Corp. 1-9 NI-488.2 User Manual for WindowsUnloading and Reloading the NI-488.2 DriverThe NI-488.2 driver

Strany 91 - Auxiliary Functions

© National Instruments Corp. 2-1 NI-488.2 User Manual for WindowsChapter 2Application Examples

Strany 92 - ! (Repeat Previous Function)

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-2 © National Instruments Corp.Example 1: Basic CommunicationThis example focuses on

Strany 93 - $ (Execute Indirect File)

Chapter 2 Application Examples© National Instruments Corp. 2-3 NI-488.2 User Manual for WindowsComputerMultimeterINITRead Measurementfrom MultimeterFi

Strany 94

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-4 © National Instruments Corp.Example 2: Clearing and Triggering DevicesThis example

Strany 95

Chapter 2 Application Examples© National Instruments Corp. 2-5 NI-488.2 User Manual for Windows GPIB CableComputer OscilloscopeINITTrigger Oscillosco

Strany 96 - Viewing Call Details

Limited WarrantyThe media on which you receive National Instruments software are warranted not to failto execute programming instructions, due to defe

Strany 97 - Set Highlight Color

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-6 © National Instruments Corp.Example 3: Asynchronous I/OThis example illustrates ho

Strany 98 - GPIB Spy Output Options

Chapter 2 Application Examples© National Instruments Corp. 2-7 NI-488.2 User Manual for WindowsComputerINITPrint Image AsynchronouslyCLEAN UPNon-GPIB

Strany 99 - Performance Considerations

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-8 © National Instruments Corp.Example 4: End-of-String ModeThis example illustrates

Strany 100 - GPIB Programming Techniques

Chapter 2 Application Examples© National Instruments Corp. 2-9 NI-488.2 User Manual for WindowsRead StatusComputerScannerINITSet EOS ModeCLEAN UPibclr

Strany 101 - Enabling HS488

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-10 © National Instruments Corp.Example 5: Service RequestsThis example illustrates h

Strany 102 - Waiting for GPIB Conditions

Chapter 2 Application Examples© National Instruments Corp. 2-11 NI-488.2 User Manual for Windows6c. When the SRQ line is asserted, the application ser

Strany 103 - Talker/Listener Applications

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-12 © National Instruments Corp.GPIB CableComputerDigital Film RecorderINITWait for th

Strany 104 - Serial Polling

Chapter 2 Application Examples© National Instruments Corp. 2-13 NI-488.2 User Manual for Windows(Continued)CLEAN UPYesWait for Film Recorder to Reques

Strany 105 - Automatic Serial Polling

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-14 © National Instruments Corp.Example 6: Basic Communication withIEEE 488.2-Complia

Strany 106 - #include "decl.h"

Chapter 2 Application Examples© National Instruments Corp. 2-15 NI-488.2 User Manual for WindowsComputer Tensile Tester 1INITTell Device 1 to Identify

Strany 107

CopyrightUnder the copyright laws, this publication may not be reproduced or transmitted in anyform, electronic or mechanical, including photocopying,

Strany 108

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-16 © National Instruments Corp.Example 7: Serial Polls Using NI-488.2 RoutinesThis e

Strany 109 - Parallel Polling

Chapter 2 Application Examples© National Instruments Corp. 2-17 NI-488.2 User Manual for WindowsComputerStrain Gauge 1INITCLEAN UPSendListWaitSRQFindR

Strany 110

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-18 © National Instruments Corp.Example 8: Parallel PollsThis example illustrates how

Strany 111

Chapter 2 Application Examples© National Instruments Corp. 2-19 NI-488.2 User Manual for Windows8. The application unconfigures all of the transducers

Strany 112 - Configuration Utility

Application Examples Chapter 2NI-488.2 User Manual for Windows 2-20 © National Instruments Corp.Example 9: Non-Controller ExampleThis example illustra

Strany 113

Chapter 2 Application Examples© National Instruments Corp. 2-21 NI-488.2 User Manual for WindowsDeviceControllerINITWait to be Talk Addressed, Listen

Strany 114 - Upper-Level Device Map

© National Instruments Corp. 3-1 NI-488.2 User Manual for WindowsChapter 3Developing Your Application

Strany 115

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-2 © National Instruments Corp.Using NI-488 Functions: One Device for Each Boa

Strany 116

Chapter 3 Developing Your Application© National Instruments Corp. 3-3 NI-488.2 User Manual for WindowsThe NI-488 board functions are compatible with,

Strany 117

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-4 © National Instruments Corp.Table 3-1 shows the condition that each bit posi

Strany 118 - Timeout Setting

© National Instruments Corp. v NI-488.2 User Manual for WindowsContents

Strany 119 - EOS Byte

Chapter 3 Developing Your Application© National Instruments Corp. 3-5 NI-488.2 User Manual for WindowsError Variable – iberrIf the ERR bit is set in t

Strany 120 - Send EOI at End of Write

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-6 © National Instruments Corp.Writing Your NI-488 ApplicationThis section disc

Strany 121

Chapter 3 Developing Your Application© National Instruments Corp. 3-7 NI-488.2 User Manual for WindowsNI-488 Program ShellFigure 3-1 is a flowchart of

Strany 122 - GPIB-PCII/IIA Mode Switch

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-8 © National Instruments Corp.General Program Steps and ExamplesThe following

Strany 123 - Exiting wibconf

Chapter 3 Developing Your Application© National Instruments Corp. 3-9 NI-488.2 User Manual for WindowsStep 3. Configure the DeviceAfter you open and

Strany 124 - Checking for Errors

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-10 © National Instruments Corp.ibrsp (ud, &StatusByte);if (ibsta & ERR

Strany 125

Chapter 3 Developing Your Application© National Instruments Corp. 3-11 NI-488.2 User Manual for WindowsWriting Your NI-488.2 ApplicationThis section d

Strany 126

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-12 © National Instruments Corp.NI-488.2 Program ShellFigure 3-2 is a flowchart

Strany 127 - Status Word Conditions

Chapter 3 Developing Your Application© National Instruments Corp. 3-13 NI-488.2 User Manual for WindowsGeneral Program Steps and ExamplesThe following

Strany 128 - RQS (dev)

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-14 © National Instruments Corp.for (loop = 1; loop <= num_Listeners; loop++

Strany 129 - LOK (brd)

ContentsNI-488.2 User Manual for Windows vi © National Instruments Corp.Chapter 3Developing Your Application...

Strany 130 - LACS (brd)

Chapter 3 Developing Your Application© National Instruments Corp. 3-15 NI-488.2 User Manual for WindowsStep 5. Configure the InstrumentAfter initiali

Strany 131 - DCAS (brd)

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-16 © National Instruments Corp.is the GPIB address of the instrument, and the

Strany 132 - Error Codes and Solutions

Chapter 3 Developing Your Application© National Instruments Corp. 3-17 NI-488.2 User Manual for WindowsCompiling, Linking, and Running Your Applicatio

Strany 133 - ECIC (1)

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-18 © National Instruments Corp.Visual BasicWith Visual Basic, you access the N

Strany 134 - EADR (3)

Chapter 3 Developing Your Application© National Instruments Corp. 3-19 NI-488.2 User Manual for WindowsSample programs using direct entry are included

Strany 135 - ESAC (5)

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-20 © National Instruments Corp.Method 2. Generate an Import Library Using imp

Strany 136 - EDMA (8)

Chapter 3 Developing Your Application© National Instruments Corp. 3-21 NI-488.2 User Manual for WindowsThe prototypes for each function can be found i

Strany 137 - EOIP (10)

Developing Your Application Chapter 3NI-488.2 User Manual for Windows 3-22 © National Instruments Corp.If GetProcAddress does not return a pointer, yo

Strany 138 - EFSO (12)

Chapter 3 Developing Your Application© National Instruments Corp. 3-23 NI-488.2 User Manual for WindowsDirect Entry with Visual BasicSee the Visual Ba

Strany 139 - ESRQ (16)

© National Instruments Corp. 4-1 NI-488.2 User Manual for WindowsChapter 4Debugging Your Application

Strany 140 - ETAB (20)

Contents© National Instruments Corp. vii NI-488.2 User Manual for WindowsMethod 2. Generate an Import Library Using implib...

Strany 141 - Customer Communication

Debugging Your Application Chapter 4NI-488.2 User Manual for Windows 4-2 © National Instruments Corp.• The board might not be properly installed and c

Strany 142 - Technical Support Form

Chapter 4 Debugging Your Application© National Instruments Corp. 4-3 NI-488.2 User Manual for WindowsHardware Information: GPIB0: an AT-GPIB/TNT boar

Strany 143

Debugging Your Application Chapter 4NI-488.2 User Manual for Windows 4-4 © National Instruments Corp.Debugging with wibicIf your application does not

Strany 144 - Documentation Comment Form

Chapter 4 Debugging Your Application© National Instruments Corp. 4-5 NI-488.2 User Manual for WindowsTable 4-1. GPIB Error CodesErrorMnemoniciberrVal

Strany 145

Debugging Your Application Chapter 4NI-488.2 User Manual for Windows 4-6 © National Instruments Corp.To test the configuration of your hardware, you c

Strany 146 - Glossary

Chapter 4 Debugging Your Application© National Instruments Corp. 4-7 NI-488.2 User Manual for WindowsCommon QuestionsCan I have the DOS and Windows dr

Strany 147

Debugging Your Application Chapter 4NI-488.2 User Manual for Windows 4-8 © National Instruments Corp.What should I type into the pop-up window that ap

Strany 148

Chapter 4 Debugging Your Application© National Instruments Corp. 4-9 NI-488.2 User Manual for WindowsWhat information should I have before I call Nati

Strany 149

© National Instruments Corp. 5-1 NI-488.2 User Manual for WindowsChapter 5wibic–Windows Interface Bus InteractiveControl Utility

Strany 150

wibic–Windows Interface Bus Interactive Control Utility Chapter 5NI-488.2 User Manual for Windows 5-2 © National Instruments Corp.1. To run wibic, dou

Strany 151

ContentsNI-488.2 User Manual for Windows viii © National Instruments Corp.! (Repeat Previous Function)...

Strany 152

Chapter 5 wibic–Windows Interface Bus Interactive Control Utility© National Instruments Corp. 5-3 NI-488.2 User Manual for Windows4. Write the functio

Strany 153

wibic–Windows Interface Bus Interactive Control Utility Chapter 5NI-488.2 User Manual for Windows 5-4 © National Instruments Corp.8. Use the read comm

Strany 154

Chapter 5 wibic–Windows Interface Bus Interactive Control Utility© National Instruments Corp. 5-5 NI-488.2 User Manual for WindowsString SyntaxYou can

Strany 155

wibic–Windows Interface Bus Interactive Control Utility Chapter 5NI-488.2 User Manual for Windows 5-6 © National Instruments Corp.Table 5-1. Syntax f

Strany 156

Chapter 5 wibic–Windows Interface Bus Interactive Control Utility© National Instruments Corp. 5-7 NI-488.2 User Manual for WindowsTable 5-2. Syntax f

Strany 157

wibic–Windows Interface Bus Interactive Control Utility Chapter 5NI-488.2 User Manual for Windows 5-8 © National Instruments Corp.wibic Syntax for NI-

Strany 158

Chapter 5 wibic–Windows Interface Bus Interactive Control Utility© National Instruments Corp. 5-9 NI-488.2 User Manual for WindowsTable 5-3. Syntax f

Strany 159

wibic–Windows Interface Bus Interactive Control Utility Chapter 5NI-488.2 User Manual for Windows 5-10 © National Instruments Corp.For a detailed list

Strany 160

Chapter 5 wibic–Windows Interface Bus Interactive Control Utility© National Instruments Corp. 5-11 NI-488.2 User Manual for Windows• Timeout setting•

Strany 161

wibic–Windows Interface Bus Interactive Control Utility Chapter 5NI-488.2 User Manual for Windows 5-12 © National Instruments Corp.• EARG–One of the l

Strany 162

Contents© National Instruments Corp. ix NI-488.2 User Manual for WindowsParallel Polling...

Strany 163

Chapter 5 wibic–Windows Interface Bus Interactive Control Utility© National Instruments Corp. 5-13 NI-488.2 User Manual for WindowsCommon NI-488.2 Rou

Strany 164

wibic–Windows Interface Bus Interactive Control Utility Chapter 5NI-488.2 User Manual for Windows 5-14 © National Instruments Corp.488.2 (0): Receive

Strany 165

Chapter 5 wibic–Windows Interface Bus Interactive Control Utility© National Instruments Corp. 5-15 NI-488.2 User Manual for WindowsSet (Select Device

Strany 166

wibic–Windows Interface Bus Interactive Control Utility Chapter 5NI-488.2 User Manual for Windows 5-16 © National Instruments Corp.ud0: ibrd 8ud0: +

Strany 167

Chapter 5 wibic–Windows Interface Bus Interactive Control Utility© National Instruments Corp. 5-17 NI-488.2 User Manual for WindowsPrint (Display the

Strany 168

© National Instruments Corp. 6-1 NI-488.2 User Manual for WindowsChapter 6GPIB Spy

Strany 169

GPIB Spy Chapter 6NI-488.2 User Manual for Windows 6-2 © National Instruments Corp.Exiting GPIB SpyExit GPIB Spy by choosing Exit from the Spy menu.C

Strany 170

Chapter 6 GPIB Spy© National Instruments Corp. 6-3 NI-488.2 User Manual for WindowsGPIB Spy Configuration OptionsCalls To HighlightYou can choose for

Strany 171

GPIB Spy Chapter 6NI-488.2 User Manual for Windows 6-4 © National Instruments Corp.Store ConfigurationYou can use this option to make the current GPIB

Strany 172

Chapter 6 GPIB Spy© National Instruments Corp. 6-5 NI-488.2 User Manual for WindowsGPIB Spy HelpYou can access online help for GPIB Spy by selecting t

Komentáře k této Příručce

Žádné komentáře