INSTALLATION GUIDE
NI TB-2706
PXI/PXIe Terminal Block for M Series and NI 6143 Devices
This installation guide describes how to install and connect signals to the NI TB-2706 terminal block
for use with PXI/PXIe M Series, NI PXI-6143, and other PXI/PXIe devices with a 68-pin VHDCI
connector.
Contents
Introduction.......................................................................................................................................... 1
What You Need to Get Started ............................................................................................................ 1
Safety Information ............................................................................................................................... 2
Connecting the Signals ........................................................................................................................ 3
Installing the Terminal Block .............................................................................................................. 5
Specifications....................................................................................................................................... 6
Where to Go for Support ..................................................................................................................... 7
Introduction
The TB-2706 is a terminal block assembly consisting of a printed circuit board, 70 screw terminals, and
a metal enclosure with strain relief hardware. The terminal block assembly connects directly to the front
panel of National Instruments PXI-622x, PXI-625x, PXIe-625x, PXI-628x, and PXI-6143 devices,
eliminating the need for an external cable.
The TB-2706 allows you to easily connect analog input, analog output, counter/timer, and digital I/O
signals to your National Instruments device. The 70 screw terminals allow access to every pin on the
connector, plus two shield screw terminals for use with a shielded cable. For M Series devices with
two connectors, this terminal block allows access to every pin on Connector 0, plus two shield screw
terminals for use with a shielded cable, but makes Connector 1 inaccessible.
Caution The TB-2706 is not designed for input voltages greater than 42 V
pk
/60 VDC, even if you
install a voltage divider that reduces the voltage to within the input range of the DAQ device. Input
voltages greater than 42 V
pk
/60 VDC can damage the TB-2706, any device connected to it, and the
host computer. Overvoltage also can cause an electric shock hazard for the operator. National
Instruments is not liable for damage or injury resulting from such misuse.
What You Need to Get Started
You need the following to set up and use your terminal block:
NI TB-2706 Terminal Block Assembly
NI TB-2706 Installation Guide
NI PXI/PXIe M Series device, NI PXI-6143, or other PXI/PXIe device with a 68-pin VHDCI
connector
M Series User Manual, S Series User Manual, or other PXI/PXIe DAQ device documentation
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - NI TB-2706

INSTALLATION GUIDENI TB-2706PXI/PXIe Terminal Block for M Series and NI 6143 DevicesThis installation guide describes how to install and connect signa

Strany 2 - Safety Information

NI TB-2706 Installation Guide 2 ni.com❑ 0.10 in. slotted screwdriver❑ Pinout label for M Series (adhered to cover of TB-2706) or pinout list for NI PX

Strany 3 - Connecting the Signals

© National Instruments Corporation 3 NI TB-2706 Installation GuideConnecting the SignalsRefer to Figure 1 as you complete the following steps to conne

Strany 4 - Pinout for PXI-6143

NI TB-2706 Installation Guide 4 ni.comFigure 2. Pinout Label for M SeriesFigure 3. Pinout for PXI-61432. Loosen or remove the strain-relief bar by l

Strany 5 - Installing the Terminal Block

© National Instruments Corporation 5 NI TB-2706 Installation Guide6. Tighten or replace the strain-relief screws.7. Replace the terminal block cover b

Strany 6 - Specifications

NI TB-2706 Installation Guide 6 ni.comSpecificationsThese specifications are typical at 25 °C unless otherwise specified.Input/OutputCaution The TB-27

Strany 7 - Where to Go for Support

© National Instruments Corporation 7 NI TB-2706 Installation GuideCE ComplianceThis product meets the essential requirements of applicable European Di

Strany 8 - 371459B-01 Apr07

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal f

Komentáře k této Příručce

Žádné komentáře