QUICK REFERENCE
NI-DMM Instrument Driver
Initialize and Close
ICON TYPE PARAMETER VALUE TO SET, COMMENTS
1
ViRsrc resourceName For Traditional NI-DAQ devices, use DAQ::
#
,
where
#
is the device number.
For NI-DAQmx devices, the device name is
assigned by Measurement & Automation
Explorer (MAX). Optionally, for all devices
you can use an IVI logical name.
ViBoolean IDQuery NIDMM_VAL_TRUE
NIDMM_VAL_FALSE
ViBoolean resetDevice NIDMM_VAL_TRUE
NIDMM_VAL_FALSE
ViSession* vi Reference to new session handle
ViRsrc resourceName For Traditional NI-DAQ devices, use DAQ::
#
,
where
#
is the device number.
For NI-DAQmx devices, the device name is
assigned by Measurement & Automation
Explorer (MAX). Optionally, for all devices
you can use an IVI logical name.
ViBoolean IDQuery NIDMM_VAL_TRUE
NIDMM_VAL_FALSE
ViBoolean resetDevice NIDMM_VAL_TRUE
NIDMM_VAL_FALSE
ViString Option String Simulate = 0, RangeCheck = 1
QueryInstrStatus = 1, Cache = 1
ViSession* vi Reference to new session handle
niDMM Initialize with Options
(niDMM_InitWithOptions)
Creates a new session to the instrument and optionally sets the initial state of
session properties.
niDMM Initialize
2
(niDMM_init)
Creates a new session to the instrument.
1 In LabWindows™/CVI™, C, and C++, constant names such as NIDMM_VAL_TRUE and
NIDMM_VAL_AUTO_ZERO_ON refer to the use of #defines in your program. In LabVIEW, these constants
refer to Boolean or ring controls with corresponding entries. For example, NIDMM_VAL_AUTO_ZERO_ON
corresponds to the LabVIEW ring control entry Auto Zero On. Refer to LabVIEW Help (Show Help) for
more details.
2 Function name for LabWindows/CVI, C, C++, and Visual Basic.
322614f.qxp 11/23/2004 10:13 AM Page 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - NI-DMM Instrument Driver

QUICK REFERENCE NI-DMM Instrument DriverInitialize and CloseICON TYPE PARAMETER VALUE TO SET, COMMENTS1ViRsrc resourceName For Traditional NI-DAQ de

Strany 2 - Measurement Options

Calibration (continued)ICON TYPE PARAMETER VALUE TO SET, COMMENTSViSession vi Session handleViString Reserved " "ViReal64* Temperature Outpu

Strany 3

©National Instruments Corporation 11 NI-DMM Instrument Driver Quick Reference©National Instruments CorporationInitialize Configure Hardware ReadCloseS

Strany 4 - Capacitance and Inductance

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer tothe Terms of Usesection on ni.com/legal for

Strany 5 - Triggers

2 ni.comInitialize and Close (continued)ICON TYPE PARAMETER VALUE TO SET, COMMENTSViSession vi Session handleConfigureICON TYPE PARAMETER VALUE TO SET

Strany 6 - Actual Values

Measurement Options (continued)ICON TYPE PARAMETER VALUE TO SET, COMMENTSViSession vi Session handleViInt32 AutoZero Default = AutoViSession vi Sessio

Strany 7 - Low-Level Acquisition

4 ni.comCapacitance and InductanceICON TYPE PARAMETER VALUE TO SET, COMMENTSViSession vi Session handleViInt32 Cable Comp Type ViSession vi Session

Strany 8 - 8 ni.com

5 NI-DMM Instrument Driver Quick ReferenceTriggersICON TYPE PARAMETER VALUE TO SET, COMMENTSViSession vi Session handleViInt32 Trigger Source Defau

Strany 9 - Calibration

NI-DMM Instrument Driver Quick Reference6 ni.comActual ValuesICON TYPE PARAMETER VALUE TO SET, COMMENTSViSession vi Session handleViReal64* autoRange

Strany 10 - Calibration (continued)

Acquisition (continued)ICON TYPE PARAMETER VALUE TO SET, COMMENTSViSession vi Session handleViInt32 Maximum Time MillisecondsViInt32 Number to Read

Strany 11 - DMM Programming Flow

Low-Level Acquisition (continued)ICON TYPE PARAMETER VALUE TO SET, COMMENTSViSession vi Session handleViInt32 Maximum Time MillisecondsViInt32 Numbe

Strany 12 - *322614F-01*

Utility (continued)ICON TYPE PARAMETER VALUE TO SET, COMMENTSViInt32 Function DC volts, AC volts, and so onViReal64 Range InputViReal64 Resolution

Komentáře k této Příručce

Žádné komentáře