Zobrazit stránku 0
OPERATING INSTRUCTIONS AND SPECIFICATIONS
NI 9225E
3-Channel, 300 V
rms
, 24-Bit, Simultaneous,
Channel-to-Channel Isolated Analog Input Module
Zobrazit stránku 0
1 2 3 4 5 6 ... 24 25

Shrnutí obsahu

Strany 1 - NI 9225E

OPERATING INSTRUCTIONS AND SPECIFICATIONSNI 9225E3-Channel, 300 Vrms, 24-Bit, Simultaneous,Channel-to-Channel Isolated Analog Input Module

Strany 2

NI 9225E Operating Instructions and Specifications 10 ni.comStopbandThe filter significantly attenuates all signals above the stopband frequency. The

Strany 3 - NI 9225E Dimensions

© National Instruments Corp. 11 NI 9225E Operating Instructions and Specificationsmodules must share a single master timebase source. Refer to the sof

Strany 4 - Connecting the NI 9225E

NI 9225E Operating Instructions and Specifications 12 ni.comSleep ModeThis module supports a low-power sleep mode. Support for sleep mode at the syste

Strany 5

© National Instruments Corp. 13 NI 9225E Operating Instructions and SpecificationsSpecificationsThe following specifications are typical for the range

Strany 6

NI 9225E Operating Instructions and Specifications 14 ni.comData rate range (fs) using external master timebaseMinimum...

Strany 7

© National Instruments Corp. 15 NI 9225E Operating Instructions and SpecificationsAccuracyInput noise ... 2 mVrms

Strany 8 - Passband

NI 9225E Operating Instructions and Specifications 16 ni.comCrosstalk (60 Hz)... –130 dBPhase match Ch-to-ch, max...

Strany 9

© National Instruments Corp. 17 NI 9225E Operating Instructions and SpecificationsTotal Harmonic Distortion (THD)(1 kHz, –20 dB) ...

Strany 10 - Alias-Free Bandwidth

NI 9225E Operating Instructions and Specifications 18 ni.comPhysical CharacteristicsIf you need to clean the module, wipe it with a dry towel.Screw-te

Strany 11

© National Instruments Corp. 19 NI 9225E Operating Instructions and SpecificationsIsolation VoltagesChannel-to-channelContinuous ...

Strany 12 - Sleep Mode

NI 9225E Operating Instructions and Specifications 2 ni.comThis document describes how to use the National Instruments 9225E and includes dimensions,

Strany 13 - Specifications

NI 9225E Operating Instructions and Specifications 20 ni.comSafety StandardsThis product meets the requirements of the following standards of safety f

Strany 14

© National Instruments Corp. 21 NI 9225E Operating Instructions and SpecificationsEnvironmentalNational Instruments C Series modules are intended for

Strany 15

NI 9225E Operating Instructions and Specifications 22 ni.comEnvironmental ManagementNI is committed to designing and manufacturing products in an envi

Strany 16

© National Instruments Corp. 23 NI 9225E Operating Instructions and SpecificationsCalibrationYou can obtain the calibration certificate and informatio

Strany 17 - Power Requirements

NI 9225E Operating Instructions and Specifications 24 ni.comWhere to Go for SupportThe National Instruments Web site is your complete resource for tec

Strany 18 - Maximum Voltage

© 2008 National Instruments Corp. All rights reserved.372618A-01 Jul08National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instrum

Strany 19 - Isolation Voltages

© National Instruments Corp. 3 NI 9225E Operating Instructions and SpecificationsNI 9225E DimensionsThe following figure shows the dimensions of the N

Strany 20 - Safety Standards

NI 9225E Operating Instructions and Specifications 4 ni.comConnecting the NI 9225EThe NI 9225E has three 2-terminal detachable screw-terminal connecto

Strany 21 - Environmental

© National Instruments Corp. 5 NI 9225E Operating Instructions and SpecificationsYou can connect ground-referenced or floating signal sources to the N

Strany 22 - Environmental Management

NI 9225E Operating Instructions and Specifications 6 ni.com Figure 3. Connecting a Grounded Signal Source to the NI 9225EFigure 4. Connecting a Floa

Strany 23 - Calibration

© National Instruments Corp. 7 NI 9225E Operating Instructions and SpecificationsThe NI 9225E analog input channels are floating with respect to earth

Strany 24 - Where to Go for Support

NI 9225E Operating Instructions and Specifications 8 ni.comUnderstanding NI 9225E FilteringThe NI 9225E uses a combination of analog and digital filte

Strany 25 - 372618A-01 Jul08

© National Instruments Corp. 9 NI 9225E Operating Instructions and Specifications Figure 6. Typical Passband Response of the NI 9225EFrequency/Data R