NI 9485 Operating Instructions 14 ni.com
Switching current, per channel
1
All channels................................ 0.75 A max
Up to four channels .................... 1.2 A max
Switching rate (90% duty cycle)
1
..... 1 operation per second
Relay open time ................................ 0.5 ms typ
Relay close time................................ 9.0 ms typ
On resistance..................................... 200 mΩ max
Off state leakage ............................... 30 μAtyp
MTBF ............................................... 2,172,740 hours at 25 °C;
Bellcore Issue 6, Method 1,
Case 3, Limited Part Stress
Method
Note Contact NI for Bellcore MTBF specifications
at other temperatures or for MIL-HDBK-217F
specifications.
1
For additional specifications related to faster switching rates and/or higher currents
at lower temperatures, go to
ni.com/info and enter the info code rd9485specs.