National-instruments PXI Terminal Block NI TB-2709 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware National-instruments PXI Terminal Block NI TB-2709. National Instruments PXI Terminal Block NI TB-2709 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 12
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
INSTALLATION GUIDE
NI TB-2709
PXI Terminal Block for S Series Devices
This installation guide describes how to install and connect signals to the
NI TB-2709 terminal block for use with PXI-6123/6133 S Series devices.
The TB-2709 can also be used with the PXI-6122/6132 devices to access
the first four AI channels.
Introduction
The TB-2709 is a terminal block assembly consisting of nine SMB
connectors and a 14-pin I/O connector. The terminal block assembly
connects directly to the front panel of National Instruments PXI-6122,
PXI-6123, PXI-6132, and PXI-6133 devices, eliminating the need for an
external cable.
Figure 1. TB-2709 Device View
1 Access Door to Configuration Switches
2 14-Pin I/O Connector (Digital Signals)
3 SMB Connectors (Analog Signals)
AI 0
AI 1
AI 2
AI 3
AI 4
AI 5
AI 6
AI 7
AI
ST
ART
TRIG
I
1
2
3
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - NI TB-2709

INSTALLATION GUIDENI TB-2709PXI Terminal Block for S Series DevicesThis installation guide describes how to install and connect signals to the NI TB-2

Strany 2 - Safety Information

NI TB-2709 Installation Guide 10 ni.comSafetyThis product is designed to meet the requirements of the following standards of safety for electrical equ

Strany 3 - Installation

© National Instruments Corporation 11 NI TB-2709 Installation GuideFinland 385 (0) 9 725 72511, France 33 (0) 1 48 14 24 24, Germany 49 89 7413130, In

Strany 4 - Signal Descriptions

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal f

Strany 5 - Measuring Floating Signals

NI TB-2709 Installation Guide 2 ni.comThe nine SMB connectors on the TB-2709 allow you to easily connect analog input signals to your National Instrum

Strany 6 - Cabling Options

© National Instruments Corporation 3 NI TB-2709 Installation GuideDo not substitute parts or modify equipment. Because of the danger of introducing ad

Strany 7

NI TB-2709 Installation Guide 4 ni.comTo connect the terminal block to the PXI module I/O connector, refer to Figure 2 as you complete the following s

Strany 8 - Specifications

© National Instruments Corporation 5 NI TB-2709 Installation GuideFigure 4. NI TB-2709 Block DiagramFor more detailed descriptions of these signals,

Strany 9 - Environment

NI TB-2709 Installation Guide 6 ni.comMeasuring Ground-Referenced SignalsIt is possible to set the switch on the TB-2709 to either the floating or gro

Strany 10 - Where to Go for Support

© National Instruments Corporation 7 NI TB-2709 Installation Guideconductors on the other end. The pigtail conductors on the cable assembly can be use

Strany 11

NI TB-2709 Installation Guide 8 ni.comTable 4 lists the National Instruments cables available for connecting the TB-2709 to both analog and digital us

Strany 12 - 374268B-01 Apr07

© National Instruments Corporation 9 NI TB-2709 Installation GuidePhysicalDimensionsHeight............ 10.7 × 8.6 ×

Komentáře k této Příručce

Žádné komentáře