Chapter 4 Digital I/O
E Series User Manual 4-10 ni.com
Figure 4-6. P0.<0..3> Configured for Digital Input, P0.<4..7>
Configured for Digital Output
Caution
Exceeding the maximum input voltage ratings, which are listed in the I/O
Terminal Summary table in the specifications document for each E Series family, can
damage the DAQ device and the computer. NI is not liable for any damage resulting from
such signal connections.
Getting Started with DIO Applications in Software
You can use the E Series device in the following digital I/O applications:
Static Digital Input
Static Digital Output
(NI 6016 and NI 6025E Devices Only) Handshaking
Note For more information about programming digital I/O applications and triggers in
software, refer to the NI-DAQmx Help or the LabVIEW 8.x Help.
+5 V
LED
TTL Signal
+5 V
Switch
I/O Connector
D GND
E Series Device
P0.<0..3>
P0.<4..7>