National Instruments NI 9233 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Komponenty podvozku National Instruments NI 9233. National Instruments NI 9233 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 34
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
OPERATING INSTRUCTIONS AND SPECIFICATIONS
NI 9233
4-Channel, ±5 V, 24-Bit IEPE Analog Input Module
ni.com/manuals
DeutschFrançais
Zobrazit stránku 0
1 2 3 4 5 6 ... 33 34

Shrnutí obsahu

Strany 1 - DeutschFrançais

OPERATING INSTRUCTIONS AND SPECIFICATIONSNI 92334-Channel, ±5 V, 24-Bit IEPE Analog Input Moduleni.com/manualsDeutschFrançais

Strany 2

NI 9233 Operating Instructions and Specifications 10 ni.comThe NI 9233 also has TEDS circuitry. For more information about TEDS, visit ni.com/info and

Strany 3 - Safety Guidelines

© National Instruments Corp. 11 NI 9233 Operating Instructions and Specificationsfrequency depends on the data rate. Figure 5 shows typical passband f

Strany 4

NI 9233 Operating Instructions and Specifications 12 ni.comThe relative phases of these signals also have a frequency-dependent delay. The variation i

Strany 5

© National Instruments Corp. 13 NI 9233 Operating Instructions and SpecificationsFigure 6. Phase Nonlinearity of the NI 92330.450.15420–2–40.100.050.

Strany 6 - Connecting the NI 9233

NI 9233 Operating Instructions and Specifications 14 ni.comStopbandThe filter significantly attenuates all signals above the stopband frequency. The p

Strany 7

© National Instruments Corp. 15 NI 9233 Operating Instructions and Specificationsshare a single master timebase source. Refer to the software help for

Strany 8

NI 9233 Operating Instructions and Specifications 16 ni.comNote The cRIO-9151 R Series Expansion chassis does not support sharing timebases between mo

Strany 9

© National Instruments Corp. 17 NI 9233 Operating Instructions and SpecificationsSpecificationsThe following specifications are typical for the range

Strany 10 - Passband

NI 9233 Operating Instructions and Specifications 18 ni.comData rates1 (fs)fs ≤ 25.65 kS/s... , n = 2, 3, ..., 25fs > 25.

Strany 11

© National Instruments Corp. 19 NI 9233 Operating Instructions and SpecificationsAC cutoff frequency responseInput range ...

Strany 12

NI 9233 Operating Instructions and Specifications 2 ni.comThis document describes how to use the National Instruments 9233 and includes specifications

Strany 13

NI 9233 Operating Instructions and Specifications 20 ni.comCommon-mode voltage range(AI– to earth ground) ... ±2 V maxIEPE excita

Strany 14 - Alias-Free Bandwidth

© National Instruments Corp. 21 NI 9233 Operating Instructions and SpecificationsOvervoltage protection (with respect to chassis ground)For an IEPE se

Strany 15

NI 9233 Operating Instructions and Specifications 22 ni.comChannel-to-channel matchingGainTypical... 0.07 dBMaximum...

Strany 16 - Sleep Mode

© National Instruments Corp. 23 NI 9233 Operating Instructions and SpecificationsCrosstalk (fin = 1 kHz)Paired channels(0 and 1, 2 and 3)...

Strany 17 - Specifications

NI 9233 Operating Instructions and Specifications 24 ni.comTotal harmonic distortion (THD)Intermodulation distortion (–1 dBFS)DIN 250 Hz/8 kHz 4:1 amp

Strany 18

© National Instruments Corp. 25 NI 9233 Operating Instructions and SpecificationsPower RequirementsPower consumption from chassisActive mode ...

Strany 19

NI 9233 Operating Instructions and Specifications 26 ni.comHazardous LocationsU.S. (UL) ... Class I, Division 2

Strany 20

© National Instruments Corp. 27 NI 9233 Operating Instructions and SpecificationsElectromagnetic CompatibilityThis product meets the requirements of t

Strany 21

NI 9233 Operating Instructions and Specifications 28 ni.comCE ComplianceThis product meets the essential requirements of applicable European Directive

Strany 22

© National Instruments Corp. 29 NI 9233 Operating Instructions and SpecificationsOperating shock(IEC 60068-2-27)... 30 g, 1

Strany 23

© National Instruments Corp. 3 NI 9233 Operating Instructions and SpecificationsSafety GuidelinesOperate the NI 9233 only as described in these operat

Strany 24

NI 9233 Operating Instructions and Specifications 30 ni.comMaximum altitude... 2,000 m Pollution Degree (IEC 60664) ...

Strany 25 - Physical Characteristics

© National Instruments Corp. 31 NI 9233 Operating Instructions and SpecificationsCalibrationYo u can obtain the calibration certificate and informatio

Strany 26 - Hazardous Locations

NI 9233 Operating Instructions and Specifications 32 ni.comWhere to Go for SupportThe National Instruments Web site is your complete resource for tech

Strany 27 - Electromagnetic Compatibility

© National Instruments Corp. 33 NI 9233 Operating Instructions and SpecificationsKorea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, Malaysia 1800 8877

Strany 28 - Shock and Vibration

© 2004–2008 National Instruments Corp. All rights reserved.373784F-01 Sep08National Instruments, NI, ni.com, and LabVIEW are trademarks of National In

Strany 29 - Environmental

NI 9233 Operating Instructions and Specifications 4 ni.comCaution Substitution of components may impair suitability for Class I, Division 2.Caution Fo

Strany 30 - Environmental Management

© National Instruments Corp. 5 NI 9233 Operating Instructions and SpecificationsSpecial Conditions for Marine ApplicationsSome modules are Lloyd’s Reg

Strany 31 - Calibration

NI 9233 Operating Instructions and Specifications 6 ni.comConnecting the NI 9233The NI 9233 has four BNC connectors that provide connections for four

Strany 32 - Where to Go for Support

© National Instruments Corp. 7 NI 9233 Operating Instructions and SpecificationsEach channel has a BNC connector to which you can connect an Integrate

Strany 33

NI 9233 Operating Instructions and Specifications 8 ni.comFigure 2. Connecting a Grounded IEPE Sensor to the NI 9233Figure 3. Connecting a Floating

Strany 34 - 373784F-01 Sep08

© National Instruments Corp. 9 NI 9233 Operating Instructions and SpecificationsThe NI 9233 analog input channels are referenced to the chassis ground

Komentáře k této Příručce

Žádné komentáře